CFM Calculator

Room size and air changes in — required airflow out.

Room & air changes

Presets are typical comfort-ventilation targets — codes and equipment specs override them.

Airflow

115 CFM

1,152 ft³ × 6 ACH ÷ 60

Cubic feet per minute to hit the air-change target

Room volume1,152 ft³
Liters / second54 L/s
m³ / hour196 m³/h
ROOM VOLUME 12′ × 12′ 8′ 1,152 FT³ — CHANGED 6× PER HOUR CFM = VOLUME × ACH ÷ 60
Bath fans: HVI sizing is 1 CFM per ft² of floor, 50 CFM minimum

Duct runs eat capacity — a fan rated at 0.1″ static pressure moves far less through long or kinked duct. Size up, vent short and straight.

Summary + link — paste into a quote or text

Estimates, not advice. This calculator exists to give you a working idea of the materials a job needs and a rough cost — not numbers to commit money or construction to. Check the figures yourself, or with an appropriately qualified professional, before you order, quote, or build. Read the full disclaimer

How this CFM calculator works

Ventilation starts with one identity — flow equals volume times how often you want that volume replaced:

CFM = L × W × H × ACH ÷ 60 · volume in ft³, air changes per hour
L/s = CFM × 0.4719 · m³/h = CFM × 1.699

Worked example: CFM for a 12 × 12 room

1,152 ft³ of room at 6 air changes per hour needs 6,912 ft³ moved every hour — divide by 60 and that's 115 CFM (54 L/s, 196 m³/h). Halve the ACH target and the fan halves with it.

Air changes per hour by room

Table 1 — Typical ACH targets
RoomACH
Bedroom5–6
Living room6–8
Kitchen7–8
Bathroom6–8
Office6–8
Basement3–4
Comfort-ventilation rules of thumb — ASHRAE 62.2 whole-house rates and local mechanical code govern where they apply.

CFM FAQ

How do you calculate CFM for a room?

CFM = room volume (ft³) × air changes per hour ÷ 60. A 12 × 12 ft room with an 8 ft ceiling is 1,152 ft³; at 6 ACH that needs 115 CFM. The calculator does the division and the metric conversions.

How many air changes per hour should a room have?

Typical comfort targets: bedrooms 5–6, living rooms 6–8, kitchens 7–8, bathrooms 6–8, basements 3–4. Code-driven ventilation (ASHRAE 62.2 whole-house rates, commercial occupancy tables) and equipment specs override these rules of thumb.

What size bathroom exhaust fan do I need?

The HVI rule is 1 CFM per square foot of floor with a 50 CFM minimum — an 8 × 10 bath wants 80 CFM. By air changes, the same room at 8 ACH computes to 85 CFM; size to the larger and vent it outdoors, never into the attic.

What is the difference between CFM and ACH?

CFM is a flow rate — cubic feet moved per minute. ACH counts how many times the room's whole volume is replaced in an hour. They convert through volume: ACH = CFM × 60 ÷ ft³, which is why the same fan gives a small room far more air changes than a big one.

How many CFM per square foot?

At 8 ft ceilings, 1 ACH is 0.133 CFM/ft² — so the common 6 ACH target is about 0.8 CFM per square foot of floor. Taller ceilings need proportionally more; that is why the calculator works from volume, not floor area.

Embed this CFM calculator on your site

Run the CFM calculator on your own site, free. Paste the snippet where you want it; the visible credit link is the only condition.

More construction calculators

Airflow 115 CFM 6 ACH room ventilation